Pile integrity test
A pile is a slender foundation element cast in the ground or driven into it. Since pile construction as well as the final product are mostly invisible, engineers have often questioned their integrity, i.e. their compliance with project drawings and specifications. In fact, experience has shown that in piles of all kinds flaws may occur. The purpose of integrity testing is to discover such flaws before they can cause any damage.
Historically, pile integrity was investigated by direct methods. These included external methods such as excavation around the pile and internal or intrusive methods, such as core-drilling . While excavation may be effective in exposing flaws in the outer part of the pile, it is usually limited to a depth of a few meters. Core drilling, on the other hand, can be carried out to a large depth provides full information, but only for a very small fraction of the pile volume.
Indirect methods, or imaging, were first developed in the early 1970s. These include three distinct methods:
* Nuclear radiation, or gamma-gamma method
* Short wave (ultrasonic) acoustic method
* Long wave (sonic) acoustic method
A pile integrity test (also known as low strain dynamic test, sonic echo test, and low strain integrity test) is one of the methods for assessing the condition of piles or shafts. It is cost effective and not very time consuming.
Pile integrity testing using low strain tests such as the TDR (Transient Dynamic Response) method, is a rapid way of assessing the continuity and integrity of concrete piled foundations. It has been used in the UK since the early 1970s, and Testconsult was the first company in the UK to obtain UKAS accreditation for this test. We use the latest portable PIT system, the TDR2, which operates in the time and frequency domain and is able to carry out advanced interpretation of data. The test measures:
Pile length, or depth to anomalies
Pile head stiffness
Pile shaft mobility – which is dependent on pile section and concrete properties
The software also produces computer simulations and impedance profiles of the test result, to analyse in detail any intermediate pile shaft responses.
The TDR test requires minimal of preparation and is able to find defects corresponding to cracks, reductions in section and zones of poor quality concrete
The test is based on wave propagation theory. The name "low strain dynamic test" stems from the fact that when a light impact is applied to a pile it produces a low strain. The impact produces a compression wave that travels down the pile at a constant wave speed (similarly to what happens in high strain dynamic testing). Changes in cross sectional area - such as a reduction in diameter - or material - such as a void in concrete - produce wave reflections.
This procedure is performed with a hand held hammer to generate an impact, an accelerometer or geophone placed on top of the pile to be tested to measure the response to the hammer impact, and a data acquisition and interpretation electronic instrument.
The test works well in concrete or timber foundations that are not excessively slender. Usually the method is applied to recently constructed piles that are not yet connected to a structure. However, this method is also used to test the integrity and to determine the length of piles embedded in structures.
Widely used in Australia now on existing structures.
This method is covered under ASTM D5882-00 - Standard Test Method for Low Strain Integrity Testing of Piles.
==References==

Rausche, F., Likins, G. E., Hussein, M.H., May, 1988. Pile Integrity By Low And High Strain Impacts. Third International Conference on the Application of Stress-Wave Theory to Piles: Ottawa, Canada; 44-55
Hussein, M.H., Garlanger, J., June, 1992. Damage Detection for Concrete Piles Using a Simple Nondestructive Method. Proceedings of the First International Conference on Fracture Mechanics of Concrete Structures: Breckenridge, CO
Likins, G. E., Rausche, F., Miner, R., Hussein, M.H., October, 1993. Verification of Deep Foundations by NDT Methods. ASCE Annual Meeting: Washington, D.C.
Massoudi, N., Teferra, W., April, 2004. Non-Destructive Testing of Piles Using the Low Strain Integrity Method. Proceedings of the Fifth International Conference on Case Histories in Geotechnical Engineering: New York, NY. (CD-ROM)
Anuj Tewari,Business Development Engineer,Complete Instrumentation Solutions,India
Ankesh Kumar Gupta (Electronics Engineer),October 2010,Rajasthan, India.
Mandip Singh Sohi, Business Development Engineer,Complete Instrumentation Solutions Pvt. Ltd., INDIA (+919899921988)
70% failures of structures occur due to foundation failure